Batteries
12V UL Certified Certified to UL1973. Consistent quality, audited over time.
12V UL-certified LiFePO4 battery
12V UL Certified
Certified to UL1973. Consistent quality, audited over time.
12V Budget Cheaper per amp-hour. Reliable today, no long-term guarantee.
12V budget LiFePO4 battery
12V Budget
Cheaper per amp-hour. Reliable today, no long-term guarantee.
48V UL Certified Required if you are permitting your system or tying…
48V UL-certified wall-mount home battery
48V UL Certified
Required if you are permitting your system or tying to the grid.
48V Budget Great build quality, but off-grid use only — not permit-legal.
48V budget server rack battery
48V Budget
Great build quality, but off-grid use only — not permit-legal.
Battery Capacity Testers After a few years, you need to test the…
ITECH battery capacity tester
Battery Capacity Testers
After a few years, you need to test the capacity of your system.
Inverters
12V Off-Grid RVs, boats, vans and small cabins. 1,000–3,000W.
Victron MultiPlus-II 12V inverter charger
12V Off-Grid
RVs, boats, vans and small cabins. 1,000–3,000W.
48V Off-Grid Run a whole house off-grid. 6,000–12,000W.
EG4 6000XP 48V off-grid inverter
48V Off-Grid
Run a whole house off-grid. 6,000–12,000W.
48V Hybrid Grid-tied plus battery backup. Certified for interconnection.
48V hybrid inverter
48V Hybrid
Grid-tied plus battery backup. Certified for interconnection.
High-Voltage Residential Highest efficiency. This is what I run in my own…
High-voltage residential inverter
High-Voltage Residential
Highest efficiency. This is what I run in my own home.
3-Phase Commercial Take an entire warehouse off-grid. Effectively unlimited capacity.
3-phase commercial inverter
3-Phase Commercial
Take an entire warehouse off-grid. Effectively unlimited capacity.
Solar Panels
Mobile Panels Lightweight and low-profile for RVs, vans and trailers.
Flexible mobile solar panel
Mobile Panels
Lightweight and low-profile for RVs, vans and trailers.
Standard Panels Best cost per watt for homes, ground mounts and carports.
Standard rigid solar panel
Standard Panels
Best cost per watt for homes, ground mounts and carports.
Solar Mounting
Ground Mount Fast to assemble, engineered and legal for permitted installs.
Solar panel ground mount
Ground Mount
Fast to assemble, engineered and legal for permitted installs.
Roof Mounted Low-profile systems engineered for secure, long-lasting roof installations.
Roof-mounted solar panels
Roof Mounted
Low-profile systems engineered for secure, long-lasting roof installations.
Solar Carports Dual-purpose structures that provide shade while generating clean energy.
Solar carport
Solar Carports
Dual-purpose structures that provide shade while generating clean energy.
Power Stations
Anker Power Stations Anker units I recommend. I like all of them.
Anker SOLIX solar generator
Anker Power Stations
Anker units I recommend. I like all of them.
UL 9540 Power Stations UL 9540 listed for home use and insurance.
Anker SOLIX S5000 power station
UL 9540 Power Stations
UL 9540 listed for home use and insurance.
System Packages
System Packages

Budget Systems

5kW Budget Handtruck

5kW Budget Handtruck

Portable 5 kWh, 120V output, builds in 25 minutes ~$2,020

10kW Budget Handtruck

10kW Budget Handtruck

Portable 10 kWh, 10 kW output ~$3,593

12kW Budget System

12kW Budget System

Whole-home backup. 12 kW inverter, 32 kWh battery from ~$4,750

System Builders

Offgrid System Builder

Offgrid System Builder

Whole-house off-grid, 5–12 kW From $5,400

Hybrid System Builder

Hybrid System Builder

Permitted grid-tied build, scales to 36 kW ~$13,500

Pre-Wired

Pre-Wired System

Pre-Wired System

EG4 XR 60. One cabinet, 60 kWh ~$20,499

Components
Battery Chargers Reliable charging for lithium batteries.
Lithium battery charger
Battery Chargers
Reliable charging for lithium batteries.
Wire & Connectors Wiring essentials for a clean, reliable setup.
Solar wire and connectors
Wire & Connectors
Wiring essentials for a clean, reliable setup.
Fuses & Breakers Essential protection for your electrical system.
DC fuses and circuit breakers
Fuses & Breakers
Essential protection for your electrical system.
Crimpers & Tools Tools for building and maintaining your system.
Battery cable crimping tool
Crimpers & Tools
Tools for building and maintaining your system.
Battery Monitors Track your battery’s power and performance.
Battery monitor with shunt
Battery Monitors
Track your battery’s power and performance.
Solar-friendly A/C Efficient cooling built for off-grid power.
Solar-friendly mini split air conditioner
Solar-friendly A/C
Efficient cooling built for off-grid power.
12V Fridges Efficient cooling for life on the road.
12V portable fridge
12V Fridges
Efficient cooling for life on the road.
Components
Van or RV

Van or RV

Mobile, 12V, tight on space and weight

Boat

Boat

Marine-rated, waterproof, heated cells

Cabin or Shed

Cabin or Shed

Small off-grid build, 12V or 48V

Whole House

Whole House

Off-grid or grid-tied with backup

12kW Budget System

10kW to 12kW inverter with a 32kWh battery. From ~$4,750

How to build a whole-home backup system from one 10kW to 12kW all-in-one inverter and a 32kWh battery.

Follow the five steps in order. You build the system, and an electrician makes the final connection to your panel.

The trade-offs. This is the lowest-cost way to back up a whole home, and it gives up three things to get there. The equipment is indoor only (the SUNON12 and EG4 12000XP are rated IP20). The system is not UL 9540 listed and the Yixiang battery is not UL listed, so some inspectors and insurance companies will not accept it. And every part is separate, so you run battery cables, AC wire and PV wire between them. My EG4 hybrid build fixes all three: outdoor-rated inverter and batteries, UL 9540 listed equipment, and less wiring.

Affiliate links below

Budget Whole-Home Backup System

Step 01: pick the inverter. Step 02: get the battery. Step 03: choose how it connects to your panel. Step 04: gather the cable and tools. Step 05: build it, one card at a time.

Also on this page: cost, meter collar transfer switches, shopping checklist, inverter settings and troubleshooting.

Everything stays off until the last card.

What this system does

What It Costs

PartRUiXU SUNON12 buildPowland 12kW buildEG4 12000XP buildSUNGOLDPOWER 10kW build
Inverter$2,099$1,050$2,100$1,422
Yixiang 32kWh battery$3,699$3,699$3,699$3,699
Total$5,798$4,749$5,799$5,121
GenerLink 30A meter collar (Option C only)$1,245$1,245$1,245$1,245
Total with meter collar$7,043$5,994$7,044$6,366

Prices checked November 2026. They change, so use the buttons below for the current price. The 40A GenerLink is $1,280. Battery cable, tools, solar panels and the electrician are extra.

The Inverter

Pick one all-in-one. The inverter, the solar charge controller and the battery charger are in the same box, so there is nothing to wire between them. All four run 120/240V split phase from a 48V battery. Three are 12kW. The SUNGOLDPOWER is 10kW, so it fits homes whose loads stay under 10,000W.

The build cards and graphics below show the RUiXU SUNON12. The others connect the same way, but their terminal layout and menus are different, so follow their manuals for those parts.

RUiXU SUNON12Powland 12kW
LOWEST PRICE
EG4 12000XPSUNGOLD­POWER 10kW
Price$2,099$1,050$2,100$1,422
Output12,000W12,000W12,000W10,000W
Solar input24,000W12,000W24,000W11,000W
MPPT range90 to 450V90 to 500V120 to 385V125 to 425V
Max PV voltage500V500V480V500V
Battery charging250A200A solar, 63A AC250A200A
Generator inputYes, separateShares the grid inputYes, separateShares the grid input

RUiXU SUNON12

12kW with 24,000W of solar input and a separate generator input. The inverter shown in every graphic on this page.

Powland 12kW

12kW with 12,000W of solar input. The lowest price of the four.

EG4 12000XP

12kW with 24,000W of solar input, a separate generator input and 100A grid bypass.

SUNGOLDPOWER 10kW

10kW with 11,000W of solar input and 20,000W peak. Use it if your loads stay under 10,000W.

The 48V Battery

One battery: the Yixiang 32kWh. It weighs about 600 lb. Without a forklift you cannot move it, so build it in the spot where it will stay. Its JK 300A BMS covers a 12kW inverter at full output, which pulls about 250A from the battery.

Yixiang 32kWh

32kWh, 51.2V, JK 300A BMS. About 600 lb, so build it in place.

How Long 32kWh Lasts

To estimate runtime, divide 32kWh by your average load in kW.

01

One battery, built in place. The Yixiang 32kWh weighs about 600 lb. Most people do not have a forklift, so build it where it will stay, close to the inverter so the battery cables stay short.

02

How long it lasts. At a steady 1,000W, 32kWh lasts 32 hours. Heavy loads shorten that fast: at 5,000W it lasts 6.4 hours, and at the inverter’s full 12,000W it lasts about 2.7 hours. Solar during the day adds hours.

Choose How It Connects to Your Home

The inverter makes the power. An electrician connects it to your house wiring. There are three ways to do it, and all three use the same inverter and battery. Pick one before you order parts.

Option A

Whole house with a transfer switch. The switch sits between your meter and your main panel. Flip it and every circuit in the house runs from the inverter. You manage the load: the inverter tops out at 12,000W (50A per leg at 240V), or 10,000W on the SUNGOLDPOWER, so the range, dryer, EV charger and central AC stay off while you are on the inverter.

Option B

Critical loads panel. A two-pole breaker in your main panel feeds the inverter, and the inverter feeds a second panel that holds the circuits you pick. Your electrician sizes that breaker and its wire. Grid power passes through until an outage, then the battery takes over on its own. The big loads stay on the main panel.

Option C

Whole house with a meter collar. A meter collar is a transfer switch that goes between your utility meter and the meter socket, so nothing changes inside your panel. Your utility has to approve it and install it. Plug the inverter into it and the whole panel runs from the inverter. Collars top out at 30A or 40A (7,200W or 9,600W), so shed the big loads first. See Meter Collar Transfer Switches below for how to set one up and what they cost.

Meter Collar Transfer Switches

A meter collar is a transfer switch that plugs in between your utility meter and the meter socket. It moves the whole panel to backup power without any work inside the panel, which makes it the quickest of the three options to set up. Your utility has to approve it and install it, because the meter belongs to them.

What they cost on Amazon

ModelRatingMost it passes from a 12kW inverterPrice
GenerLink with surge protection30A, 240V7,200W$1,245
GenerLink non-surge40A, 240V9,600W$1,280

Prices checked November 2026. Both kits come with a 20 ft cord. The collar’s 30A or 40A rating, not the 12kW inverter, sets how much power reaches your panel, so keep the house under it.

How to use one with this system

  1. Call your utility and ask whether they allow meter collar transfer switches and which models they approve. Some run their own program. PG&E calls theirs the Backup Power Transfer Meter.
  2. Buy an approved model and have the utility install it.
  3. Have your electrician wire the inverter’s LOAD (AC OUT) through a two-pole breaker to an outlet that matches the collar’s cord.
  4. On the SUNON12, set N Line Ground (AC menu) to Disabled so the inverter has a floating neutral. PG&E’s guide for its program recommends a floating-neutral source.
  5. In an outage, turn off the range, dryer, central AC and EV charger, then plug the cord in. The collar disconnects the grid and the whole panel runs from the inverter.
  6. Do not feed the inverter’s GRID (AC IN) from the house while the collar is in use. Charge the battery from solar or a generator.

GenerLink 30A with Surge

Meter collar transfer switch. Passes up to 7,200W. Built-in surge protection, 20 ft cord.

GenerLink 40A Non-Surge

Meter collar transfer switch. Passes up to 9,600W. No surge protection, 20 ft cord.

Everything Else You Will Need

Battery cables: the SUNON12 manual calls for 2/0 AWG copper up to 12 ft and 4/0 AWG from 12 to 20 ft. At full output a 12kW inverter pulls about 250A from the battery. Keep the cables short and make the red and black the same length.

From the hardware store or your electrician: copper wire for the AC side, a two-pole breaker that fits your panel, and the transfer switch, critical loads panel or meter collar outlet. Your electrician sizes the wire and the breaker. The SUNON12 manual lists 2/0 AWG for the grid terminals and 3 AWG for the load terminals.

2/0 AWG Battery Cable Kit

Wire, lugs and heat shrink for the two cables between the battery and the inverter

Ratchet Cable Cutter

Cuts 2/0 battery cable square. Also cuts the AC wire

Large Gauge Cable Stripper

Strips the 2/0 battery cable without cutting strands

Large Wire Crimper

Battery powered hydraulic crimper for the 2/0 lugs

Hydraulic Crimper

Manual, lower cost way to crimp the 2/0 lugs. Slower, same result

Heat Shrink with Adhesive

Seals each lug after you crimp it

Heat Gun

Shrinks the heat shrink on the battery cable lugs

Inch Pound Torque Wrench

Tightens the battery and inverter studs to the torque in their manuals (79.7 lb-in on the SUNON12)

Torque Screwdriver

Tightens the AC and PV screw terminals to spec

Multi-Size Wire Stripper

Strips the smaller AC wire and the 10 AWG PV wire

Ferrule Crimping Kit

Crimper and ferrules for the stranded wire going into screw clamps and the PV terminals

Clamp Meter

Checks battery and solar polarity and voltage before you turn anything on

10 AWG MC4 Extension Cable

Connect any solar panels to this system with this cable

Solar Disconnect Switch

One per string. Pick the DC1000V 30 Amp option. The 400V options are rated below the 500V strings on this system.

Shopping Checklist

Order online

  • 1 inverter (Step 01)
  • 1 Yixiang 32kWh battery (Step 02)
  • 1 2/0 AWG battery cable kit (4/0 AWG if the run is over 12 ft)
  • 1 MC4 extension cable and 1 PV disconnect for each solar string
  • Solar panels
  • Any tools above that you do not own
  • For Option C: a meter collar your utility approves

Hardware store or electrician

  • Copper wire for GRID and LOAD, sized by your electrician
  • Two-pole breaker that fits your panel
  • Transfer switch, critical loads panel or meter collar outlet
  • Network cable for the battery communication port
  • Wood screws for the inverter wall bracket if your wall is wood (the SUNON12 box includes masonry bolts)

Build It Step by Step

Do the cards in order. Keep every breaker and disconnect off until card 08. If a step is not clear, stop and ask on the DIY Solar Forum or hire a professional.

01

Learn the connections.

  1. Take the lower front cover off the inverter to reach the wiring box.
  2. Left: the battery breaker and the BAT+ and BAT− studs.
  3. Middle: the comm board, the four AC breakers, the neutral bar, the PE bar and the GRID lugs.
  4. Right: the PV1 and PV2 terminals.

02

Mount the inverter.

  1. Pick an indoor wall near your panel and the battery.
  2. Leave 19.7 inches (50 cm) open above, below and on each side.
  3. Mark the holes with the drill template from the box, then mount the wall bracket.
  4. It weighs 84.9 lb. Lift it onto the bracket with a helper.

03

Connect the battery.

  1. Put the battery in its final spot. Both battery breakers off: the one in the inverter and the one on the battery.
  2. Build the two 2/0 AWG cables (see Build the Battery Cables below).
  3. Red cable: battery + to BAT+.
  4. Black cable: battery − to BAT−.
  5. Torque to 79.7 lb-in (9 Nm), then tug each cable.

04

Plug in the communication cable.

  1. Plug a network cable into the battery’s CAN port.
  2. Plug the other end into the BMS port on the inverter’s comm board.
  3. After startup, set BMS Select, BMS Protocol and Battery Type to match the battery (see the settings table below).

05

Wire the AC side.

  1. GRID (AC IN) comes from the grid breaker: L1, L2 and neutral.
  2. LOAD (AC OUT) goes to the transfer switch, critical loads panel or meter collar outlet.
  3. Neutrals land on the neutral bar, grounds on the PE bar.
  4. The manual lists 2/0 AWG copper for GRID and 3 AWG for LOAD.
  5. Have your electrician make these connections.

06

Run the solar wires.

  1. Run 10 AWG PV wire from each string to a disconnect. Disconnect off.
  2. String 1 lands on PV1, string 2 on PV2. Match the + and − printed above each terminal.
  3. Crimp a ferrule on each stranded PV wire.
  4. Plug in the panels at night or with them covered.

07

Check the string voltage.

  1. Find Voc on the label on the back of a panel.
  2. Multiply it by the number of panels in the string.
  3. On the SUNON12 the result must be between 90V and 450V.
  4. It must stay under 500V on the coldest morning.
  5. Powland: 500V max, 22A per input. EG4 12000XP window: 120V to 385V, 480V max. SUNGOLDPOWER window: 125V to 425V, 500V max.

08

Start it up in order.

  1. Ground wire on, cover on, polarity checked with a meter.
  2. Battery breaker in the wiring box on. Every other breaker off.
  3. Grid breaker on, then the PV switch on the side of the case.
  4. Battery on, then press the power button on the right side.
  5. Check the lights, then turn on the remaining breakers. Loads on one at a time, smallest first.

Settings to Change After First Startup

Set these on the SUNON12 touchscreen (Setting, then the menu listed) before you put a load on it. The Powland, EG4 12000XP and SUNGOLDPOWER use different menus, so follow their manuals.

MenuItemSet it to
BatteryBattery TypeLF16 (lithium iron phosphate, 16 cells). The Yixiang 32kWh is a 16-cell pack.
BatteryBMS SelectCAN-BMS or 485-BMS, to match the battery port you plugged into.
BatteryBMS ProtocolThe protocol Yixiang lists for RUiXU inverters.
EMSMax Charge Current. Default is 60A, max 250A.No higher than your battery allows.
EMSOutput source priorityBattery Mode runs loads from the battery first and uses the grid as backup. Grid Mode uses the grid first.
ACN Line GroundMatch where your neutral is bonded. Disabled for a meter collar. Ask your electrician for Options A and B.

Build the Battery Cables

You need two cables: one red, one black, both 2/0 AWG and the same length. Measure from the battery terminals to the inverter studs with the battery in its final spot, then add a little slack.

01

Cut it square. Cut the 2/0 cable to length with the ratchet cutter. Cut the red and the black to the same length.

02

Strip to the barrel depth. Hold the lug next to the cable and strip only as much insulation as the barrel is deep. Do not cut any strands.

03

Crimp the lug. Slide a piece of heat shrink onto the cable first. Push the copper to the end of the barrel and crimp it with the 2/0 die. Pull on the lug. It must not move.

04

Seal it. Slide the heat shrink over the barrel and shrink it with the heat gun. Repeat for all four cable ends.

Crimp Ferrules on Stranded Wire

When a screw clamp lands on bare stranded wire it spreads the strands apart, some miss the clamp, and the connection can loosen and heat up over time. A ferrule turns the strands into one solid pin the clamp can grip. Use one on the stranded wire that goes into the SUNON12’s smaller clamps and terminals: the 6 AWG generator and smart load wires and the 10 AWG PV wire. The kit is in Step 04 above.

01

Strip to the barrel length. Pick the ferrule that matches your wire gauge (the kit lid lists the sizes). Strip the insulation back to the length of the ferrule’s metal barrel without nicking or cutting any strands.

02

Twist and insert. Give the strands a light twist so none stick out, then push the wire in until the insulation seats inside the plastic collar. The copper should end flush with the end of the barrel.

03

Crimp it. Set the barrel in the crimper’s hex die and squeeze until the ratchet releases. The hex crimp packs every strand into one solid pin.

04

Land it in the terminal. Push the crimped ferrule all the way into the terminal and tighten the screw. Tug on the wire. If it moves, tighten again.

Recommended Solar Panel Array

The SUNON12 has two solar inputs. Each one takes a string of panels wired in series, and each string has to land between 90V and 450V to charge.

To size a string, multiply the Voc on your panel’s label by the number of panels in it. Do not exceed 500VDC at the PV input.

The SUNON12 takes up to 12,000W of panels on each input, 24,000W total, with a 32A limit per input. The Powland takes 12,000W total: 6,000W and 22A per input, 500V max. The EG4 12000XP takes 24,000W at 120V to 385V, 480V max. The SUNGOLDPOWER takes 11,000W at 125V to 425V, 500V max.

Solar panel array on a tilt mount

Charging From a Generator

In a long outage, a generator can recharge the battery. The SUNON12 has its own generator input (GEN L1 and L2 with a 63A built-in breaker), so the generator does not share the grid terminals.

  1. Use a generator with a 240V split-phase output. The SUNON12 accepts 85 to 140V on each leg.
  2. Have your electrician wire an inlet to the GEN terminals with 6 AWG copper.
  3. Set Gen Charge Current (EMS menu, default 60A, up to 160A) low at first so a small generator is not overloaded. Gen Boost lets the battery help an undersized generator.
  4. The dry contact on the comm board can start and stop a generator that has a remote start input.

On an inverter without a generator input, never connect the generator and the grid to AC IN at the same time.

If It Does Not Start

What you seeWhat to do
Blank screenTurn on the battery breaker in the wiring box and the battery, then press the power button on the right side.
Fault 05, battery not connectedCheck the battery cables and both battery breakers.
Fault 49, BMS communication errorCheck the network cable, BMS Select and BMS Protocol.
Fault 10, battery output overloadTurn off loads until you are under 12,000W.
Fault 09, bypass overloadTurn off loads. The Load breaker passes up to 125A from the grid.
Fault 48, grid phase errorGRID (AC IN) must be 240V split phase: L1, L2 and neutral.
Fault 18, PV over-voltageOpen the PV disconnect. The string is over 500V. Remove panels from it.
Fault 02, battery under-voltage protectionCharge the battery from solar, the grid or a generator.

The fault codes come from the SUNON12 manual. The Powland, EG4 12000XP and SUNGOLDPOWER use their own codes.

Permits, Inspection and Insurance

The Yixiang battery is not UL listed. As I say on my budget battery page, uncertified batteries carry some risk, because the company can change cells or BMS at any time. Ask your electrician, your inspector and your insurance company what they require before you order. For Option C, your utility decides whether a meter collar is allowed.

If you need a listed system, see my 48V UL certified batteries and the EG4 hybrid build.

Reset and Set Up the Yixiang JK BMS

The Yixiang 32kWh uses a JK 300A BMS. When the battery connects to a 12kW inverter, the inrush current into the inverter’s capacitors can trip the BMS overcurrent protection. The battery then cuts its output, and the inverter shuts off or shows Fault 05 (battery not connected). The BMS has to be reset and its settings changed before it will hold. Turning on Dis-limiter in the JK BMS app fixed it on my system.

JK BMS settings for this system

These start from Gobel Power’s JK settings sheet for EVE 314Ah cells, with the capacity and current limits changed for the Yixiang 32kWh and a 12kW inverter.

Reset the BMS after a trip

  1. Press the inverter’s power button to turn it off and turn off all loads.
  2. Turn off the battery breaker in the inverter’s wiring box.
  3. Open the JK BMS app on your phone and connect to the battery over Bluetooth. The alarm list shows which protection tripped.
  4. Wait for the recovery time (70 seconds with the settings below), or press the RST button on the BMS to restart it. If the alarm stays, turn the battery off and back on.
  5. In the app, turn on Dis-limiter and check the settings in the table below.
  6. Start the system again in the manual’s order: inverter battery breaker on first, then the battery, then the power button. Turning the battery on last lets the BMS precharge the inverter’s capacitors before its main switches close.
SettingSet it toWhy
Dis-limiterOnStops the inverter inrush from tripping the battery.
Charge, Discharge, BalanceOnNormal operation.
Disable Temp. Sensor, EmergencyOffBoth turn off protection.
Smart SleepOffKeeps the BMS awake during long stretches on the grid.
Cell Count1616 cells in series, 51.2V.
Battery Capacity (AH)628Sets the state of charge math.
Cell OVP / OVPR3.65V / 3.40VStops charging if a cell runs high.
Cell UVP / UVPR2.60V / 2.65VStops discharging if a cell runs low.
SOC-100% Volt.3.41VResets the gauge to 100% at full charge.
Vol. Cell RCV / RFV3.45V / 3.40VCharge and float voltage sent to the inverter over CAN.
Continued Discharge Curr.300AThe BMS rating. A 12kW inverter pulls about 250A at full output.
Discharge OCP Delay / OCPR Time300s / 70sRides through motor starts; resets on its own after 70 seconds.
Continued Charge Curr.250AThe SUNON12 maximum. Set the inverter’s Max Charge Current at or below this.
Charge OCP Delay / OCPR Time3s / 60sGobel Power values.
Balance Trig. Volt. / Max Balance Cur.0.01V / 2.0AGobel Power values.
Charge UTP / UTPR2°C / 5°CNo charging below freezing.
Charge and Discharge OTP / OTPR60°C / 55°CGobel Power values.
CAN Protocol No.The number Yixiang lists for RUiXULets the inverter read the BMS.

If the battery still trips after these changes, post your JK alarm list and settings screenshots on the DIY Solar Forum.

My Latest Videos

Visit my Channel
Will Prowse

Visit my Channel

DIY Solar Power with Will Prowse